-40%

Multifunction Thermocouple RTD Process Calibrator 2in1 DCV Ohm Source Output

$ 250.8

Availability: 100 in stock
  • Country/Region of Manufacture: China
  • Condition: New
  • Restocking Fee: No
  • MPN: 7212
  • Model: 7212
  • Item must be returned within: 30 Days
  • All returns accepted: Returns Accepted
  • Brand: generic
  • Return shipping will be paid by: Buyer
  • Refund will be given as: Money Back

    Description

    Note: USB function is not available.
    Multifunction Temperature
    Calibrator
    (referred to as
    “The Calibrator”
    )
    is a handheld, high capacity and rechargeable battery-operated instrument that measures and sources electrical and physical parameters. Such as measures and simulates a variety of thermocouple (TC) and Resistance Temperature Detector
    (RTD).
    See Table 1.
    In addition to the functions listed in Table 1, the Calibrator also has the following characteristics
    1
    .
    A split-screen display. The upper display allows users to measure volts, current. The lower display allows the user to measure and source Millivolt, resistance temperature detectors, thermocouples and ohms.
    2
    .
    A thermocouple (TC) input/output terminal with Cold Junction Compensation, ambient temperature can be set and calibrate within the menu function.
    3
    .
    Each parameters can manual and automatic stepping and ramping output, signal output can be arbitrarily set within the 0% and 100% of the value.
    4
    .
    In the configuration menu can be set manually: Power off time for Instrument, Backlight off time, Screen Contrast, Cold Junction compensation ON/OFF, HART resistance ON/OFF and etc.
    5
    .
    Have calendar clock function, it can be calibrated in configuration menu.
    6. It can be store 8 sets of measurement and output data and call the showing at any time, all the settings and the functions of the last operation be auto-stored after power off.
    7. High capacity rechargeable battery pack with power adapter within integrated charge-management functions.
    8
    .
    Novel shape and large screen dot-matrix graphic display.
    Table 1. Summary of Source and Measure Functions
    Function
    Measure signal
    Output
    DC Voltage (the upper display)
    0.000-30.000 V
    DC Current (the upper display)
    0.000-24.000 mA
    Loop
    power (the upper display)
    0.000-24.000 mA
    DC Millivolt
    -10.000mV-80.000mV
    -10.000mV-80.000mV
    Resistance
    0Ω to 400.00Ω
    400.0Ω to 4000.0Ω
    5.00Ω to 400.00Ω
    400.0Ω to 4000.0Ω
    Thermocouple (TC)
    Type: S, R, B, K, N, E, J, T(mV)
    Resistance Temperature Detector (RTD)
    Pt100(385) Pt100(3926) Pt100(3916) Pt200(385)
    Pt500(385) Pt1000(385) Cu100(ITS) Cu50(ITS)
    Other functions
    Stepping output, Ramping output, Store data, a split-screen display.
    Technical Index:
    Specifications are based on a one year calibration cycle and apply from +
    18 °C
    to +
    28 °C
    unless stated otherwise. All specifications assume a five-minute warmup period.
    The presentation of accuracy is: ± (reading value *% + lower order digits)
    Temperature coefficient:
    -10 ℃
    to
    18 ℃
    , +
    28 ℃
    to
    55 ℃
    : ±0.005 % of range per °C
    1
    .
    DC Voltage Measurement
    Range
    Resolution
    Accuracy
    0-30.000V

    upper display

    0.001V
    0.02%+3
    -10.000-80.000mV
    0.001mV
    0.01%+10
    2
    .
    DC Voltage output
    Range
    Resolution
    Accuracy
    -10.000—80.000mV
    0.001mV
    0.01%+10
    3
    .
    DC Current (Milliampere) Measurement
    Range
    resolution
    Accuracy
    0—24.000mA

    upper dispaly

    0.001mA
    0.02%+4
    4.
    Ohms Measurement
    Ohms
    Range
    Accuracy±Ω
    4-wire

    4W

    2-wire

    2W

    and 3-wire

    3W

    0—400.00Ω
    0.1Ω
    0.15Ω
    400.0—4000.0Ω
    0.5Ω

    Excitation Current: 0.2mA.Maximum input voltage: 30V.2-wire: Does not include lead resistance.
    3-wire:
    Assumes matched leads with a total resistance not exceeding 100 Ω.
    5. Ohms Source
    Range
    Excitation Current from Measurement Device
    Accuracy±Ω
    Resolution
    5.00Ω to 400.00Ω
    0.15mA-0.5mA
    0.1Ω
    0.01Ω
    5.00Ω to 400.00Ω
    0.5mA-2mA
    0.05Ω
    0.01Ω
    400.0 to 1500.0Ω
    0.05mA-0.8mA
    0.8Ω
    0.1Ω
    1500.0Ω to 4000.0Ω
    0.05mA-0.4mA
    1.5Ω
    0.1Ω
    6.
    Temperature ,Thermocouples
    Type
    Range
    Resolution
    Measurement and Source Accuracy±

    S
    -50.0

    to
    0

    0.1

    /
    0.1
    F
    1.5

    0

    to
    500.0

    0.1

    /
    0.1
    F
    1

    500.0

    to
    1760.0

    0.1

    /
    0.1
    F
    0.8

    R
    -50.0℃
    to
    0℃
    0.1℃
    /
    0.1℉
    1.5℃
    0℃
    to
    500.0℃
    0.1℃
    /
    0.1℉
    1℃
    500.0℃
    to
    1760.0℃
    0.1℃
    /
    0.1℉
    0.8℃
    B
    200℃
    to
    800℃
    800℃
    to
    1800℃
    1℃
    /
    1℉
    2.2℃
    1.8℃
    K
    -200.0℃
    to
    1370.0℃
    0.1℃
    /
    0.1℉
    0.8℃
    N
    -200.0℃
    to
    1300.0℃
    0.1℃
    /
    0.1℉
    0.8℃
    E
    -200.0

    to
    1000.0℃
    0.1℃
    /
    0.1℉
    0.5℃
    J
    -200.0℃
    to
    1200.0℃
    0.1℃
    /
    0.1℉
    0.5℃
    T
    -200.0℃
    to
    400.0℃
    0.1℃
    /
    0.1℉
    0.5℃
    The thermocouple complies with ITS-90.
    If open the cold junction compensation (
    CJC
    ON
    ), additional plus ±
    0.3 ℃
    .
    7.Temperature, Resistance Temperature Detectors (RTD)
    Type
    Range
    Accuracy±

    Measure 4-wire

    Measure 2-wire and 3-wire

    Output

    Pt100-385
    -200.0

    -850.0

    0.3

    0.5

    0.3

    Pt100-3926
    -200.0

    -850.0

    0.3

    0.5

    0.3

    Pt100-JIS
    -200.0

    -850.0

    0.3

    0.5

    0.3

    Pt200-385
    -200.0

    -250.0

    0.2

    0.3

    0.2

    250.0

    -630.0

    0.8

    1.6

    0.8

    Pt500-385
    -200.0

    -500.0

    0.3

    0.6

    0.3

    500.0


    630.0

    0.4

    0.9

    0.4

    Pt1000-385
    -200.0

    -100.0

    0.2

    0.2

    0.3

    100.0

    -630.0

    0.2

    0.3

    0.3

    Cu100
    -50.0℃
    -150.0℃
    0.4℃
    0.6℃
    0.4℃
    Cu50
    -50.0℃
    -150.0℃
    0.4℃
    0.6℃
    0.4℃
    Resolution: 0.1 ° C, 0.1 ° F.
    Allowable excitation current (Source): Pt100-385, Pt100-392, Pt100-JIS, Pt200-385: 0.15 to 3.0 mA
    Pt500-385: 0.05 to 0.80mA; Pt1000-385: 0.05 to 0.40mA.
    *
    2-wire: Does not include lead resistance.
    *3-wire: Assumes matched leads with a total resistance not exceeding 100 Ω.
    8. Loop Power
    Voltage: 24 V; Maximum current: 22 mA ; Short circuit protected.
    9. Complex Index
    Operating temperature
    -10

    to
    50

    Storage temperature
    -20

    to
    70

    Operating altitude
    3000 meters above mean sea level
    Relative Humidity (% RH operating without condensation)
    75%(
    30℃
    to
    40℃
    ) / 45%(
    40℃
    to
    50℃
    )
    35%(
    50℃
    to
    55℃
    ) / uncontrolled <
    10 °C
    Stability
    ± 0.005 % of range/°C outside of 23 ± 5 °C
    Vibration
    Random,
    2g
    , 5 to 500 Hz
    Safety
    EN 61010-1:1992
    Protection Class
    Pollution Degree II
    Protection Class

    L*W*H

    224mm
    *
    172mm
    *
    65mm
    Weight
    About
    1.5kG
    (Include the battery)
    Accessories:
    a pair of Test leads, a power adapter(US, Euro, UK or AU plug),  8PCS x
    Ni-MH rechargeable battery 1.2V AA, a t
    hermocouple conversion plug, Carrying case. PDF manual.